hvac-solutions Products
Heat Exchanger

Titanium Heat Exchanger

The RVBH-T Titanium Heat Exchanger is a high-performance thermal solution designed for efficient heating and cooling across industrial and commercial applications. Built with corrosion-resistant titanium twisted tubes, it delivers superior heat transfer, long service life, and reliable operation even in harsh environments such as seawater, chemicals, and wastewater systems. Its compact, durable design ensures low maintenance, energy efficiency, and consistent performance in demanding conditions.

Technical Edges

1.Superior Heat Transfer Performance: The advanced corrugated (twisted) tube design significantly enhances turbulence within the fluid, resulting in outstanding heat transfer efficiency. Compared to conventional straight titanium tubes of the same diameter, wall thickness, and length, thermal performance is improved by 1.3 to 2.6 times, enabling faster and more energy-efficient temperature control.

2.Exceptional Corrosion Resistance & Reliability: Manufactured using Grade 1 titanium in compliance with GB/T 3625-1995 standards, these heat exchangers are engineered for the most demanding environments. Each unit undergoes rigorous quality testing, including:

a.High-pressure testing up to 43 bar

b.Precision halogen leak detection

c.100,000-cycle fatigue testing at 4.5 bar

d.This ensures long-term durability, zero leakage, and reliable operation even in highly corrosive media such as seawater, acids, and alkaline solutions.

3.Enhanced Anti-Scaling & Low Maintenance Design: The seamless, weld-free corrugated tube construction minimizes weak points and significantly reduces the risk of leakage. The induced turbulent flow effectively inhibits scale formation and fouling, leading to:

a.Extended service life

b.Consistent thermal efficiency

c.Reduced maintenance and operational costs

4.Robust and Corrosion-Resistant Shell Construction: The outer shell is manufactured using high-grade PVC, offering excellent resistance to acids, alkalis, and corrosive environments. Designed to withstand operational pressure while maintaining structural integrity, the unit is also RoHS compliant, ensuring environmental safety and sustainability.

5.Compact, Lightweight & Installation-Friendly Design: With a sleek and compact structure, the heat exchanger delivers high performance without occupying excessive space. Its lightweight construction, combined with strong strain compensation capability, allows for easy handling and installation across a wide range of applications.

Specification

Technical Specification (PVC Shell for Swimming Pool Heat Pump)

Item Heating Capacity (KW) Water Flow (m³/h) PVC shell dimention A*B (mm) Titanium tube specifications (mm) Refrigerant inlet & outlet (mm) Refrigerant inlet & outlet (mm)
RVBHT038-B1 3.8 1.8 Φ110*330 Φ12.7*0.6 Φ12.7/Φ12.7 50
RVBHT045-B1 4.5 2 Φ110*380
RVBHT053-B1 5.3 2.5 Φ110*430
RVBHT078-B1 7.8 3.5 Φ110*470
RVBHT080-B1 8 3.8 Φ110*500
RVBHT095-B1 9.5 4.2 Φ160*470
RVBHT113-C1 11.3 5 Φ160*480 Φ16*0.6
RVBHT120-C1 12 5.3 Φ160*530
RVBHT125-C1 12.5 5.5 Φ200*550
RVBHT140-C1 14 6.2 Φ200*620
RVBHT170-C1 17 7.5 Φ200*660
RVBHT210-D1 21 9.2 Φ200*760 Φ19*0.6
RVBHT260-D1 26 12 Φ200*760
  • The dimensions listed in the table are for reference only; final specifications are subject to the approved drawings.
  • Heating conditions: ambient temperature 20°C dry bulb / 15°C wet bulb, inlet water temperature 26°C, outlet water temperature 28°C. Maximum outlet water temperature: 35°C.

Technical Specification (PVC Shell for Cooling Water)

Item Cooling Capacity (KW) Water Flow (m³/h) PVC shell dimention A*B (mm) Titanium tube specifications (mm) Refrigerant inlet & outlet (mm) Refrigerant inlet & outlet (mm)
RVBHT035V-B1 3.5 0.8 Φ140*500 Φ12.7*0.6 Φ12.7/Φ12.7 50
RVBHT050V-B1 5 1 Φ160*575
RVBHT075V-C1 7.5 1.3 Φ160*480 Φ16*0.6 Φ12.7/Φ12.7
RVBHT100V-C1 10 1.8 Φ200*550
RVBHT125V-D1 12.5 2.2 Φ200*640 Φ19*0.6 Φ12.7/Φ19
RVBHT150V-D1 15 2.6 Φ250*590
RVBHT180V-D1 18 3.1 Φ250*650
RVBHT200V-D1 20 3.5 Φ250*715
RVBHT250V-D2 25 4.3 Φ250*810
RVBHT300V-D2 30 5.2 Φ250*1110
RVBHT375V-D2 37.5 6.5 Φ250*1310
RVBHT500V-D2 50 11 2-Φ250*810

Note:

  • The dimensions listed in the table are for reference only; final specifications are subject to the approved drawings.
  • Heating conditions: ambient temperature 20°C dry bulb / 15°C wet bulb, inlet water temperature 24°C, outlet water temperature 19°C.

Working Conditions

PVC–Titanium Heat Exchanger Refrigerant side (inside titanium twisted tube) Water side (in the shell)
Maximum Working Pressure 5.3MPa 0.5 MPa (default); 0.6–0.8 MPa
Normal Working Pressure ≤4.5MPa 0.3–0.4 MPa
Operating Temperature Range -50–150°C -10–35°C
Applicable Medium / Refrigerant Type R22, R134a, R404a,
R407c, R410a, R417a,
R600a, etc.
Seawater, electroplating solutions,
antifreeze, swimming pool water,
groundwater, beverages, etc.
Remarks / Notes 1. Before initial operation, ensure the water system is completely vented; system pressure must not exceed the maximum allowable pressure.
2. Maintain clean water quality; it is recommended to install a filter and perform regular cleaning.
3. When the unit is not in use for an extended period, drain all liquid to prevent contamination, scaling, or freezing that may cause shell cracking.